Potter Electric Signal (P2S-000) Lv. 2 high security contact

$458.04

SKU: P2S-000 Brand:

1 in stock

The Potter Electric Signal P2S-000 is a Level 2 high-security door contact. Specifically, it is listed to UL 634 Level 2 — the standard for sensors used in SCIFs, government facilities, financial institutions, nuclear sites, data centers, and military applications. The P2S-000 is the single-contact, no-resistor variant in the P2 Series HSS family.

First, the switch mounts in or near the door frame opposite a matching magnet. Then any opening, sliding, or magnetic-defeat attempt drops the alarm contact. As a result, the access-control or intrusion panel reports an immediate breach. Furthermore, a closed-loop tamper circuit signals any attempt to remove or compromise the device itself.

Why the Potter Electric Signal P2S-000 is a Level 2 high-security contact

UL 634 Level 2 requires resistance to a wide range of defeat methods. The P2S-000 resists external and internal magnetic defeat. In addition, the switch resists permanent contact welding from lightning, power surges, and stun-gun discharges. Also, the unit’s installation gap is limited to a maximum of 1/8″ so the sensor can meet UL 634 Level 2 compliance. Therefore, accuracy during installation is critical.

Verified specifications

  • Listing: UL 634 Level 2 high security
  • Case: aluminum with silver-grey anodized finish
  • Wire type: solid color-coded lead wires
  • Alarm contact: single, closed or open loop configurable (P2S = single contact, no resistor)
  • Tamper circuit: closed loop
  • Maximum current: 0.25 A resistive
  • Maximum voltage: 30 VDC
  • Defeat resistance: external and internal magnets, contact welding (lightning, surges, stun guns)
  • Maximum installation gap: 1/8″ (for UL 634 Level 2 compliance)
  • Mounting: cross-hole design — eliminates L and Z brackets on most installations

Common applications

Integrators specify the P2S-000 for SCIFs, vault rooms, ammunition magazines, secure server cages, and high-value financial spaces. For example, defense, intelligence, and central-bank facilities frequently require UL 634 Level 2 contacts at every secured opening. Also, the no-resistor “000” variant gives the integrator full freedom to use any panel-side EOL scheme required by the alarm system.

For more information, contact the Life Safety Consultants team at (888) 557-0558, or email us at: sales@lifesafetycom.com

Additional information

Weight 1.5 lbs
Dimensions 9.25 × 6.5 × 2 in
Condition

New

Manufacturers

Potter

Part Type

Replacement Part