Simplex (2190-9163) Zone Addressable Module (ZAM) 0617610

$299.00

SKU: 2190-9163 Brand:

IDNet and MapNet II surface mount, control relay ZAM

The Simplex 2190-9163 Zone Addressable Module (ZAM) is a surface-mount control relay device that receives power and communication from a two-wire IDNet or MAPNET II circuit. The 2190-9163 provides a DPDT (double-pole, double-throw) control relay output for addressable control functions including elevator capture, HVAC shutdown, pressurization fan control, and fire/smoke damper control.

  • IDNet and MAPNET II two-wire addressable control relay module
  • DPDT relay output for control functions
  • Applications: elevator capture, HVAC control, pressurization fan control, damper control
  • Surface-mount enclosure; Dimensions: 5.5 x 5.5 x 2 in
  • Compatible with 2120, 4008, 4020, 4100, 4100ES, 4100U, 4010ES, and 4010 series panels
  • Condition: New; Weight: 0.25 lb

Compatible Panels: Simplex 2120, 4008, 4010, 4010ES, 4020, 4100, 4100ES, 4100U series control panels.

The 2190-9163 is a control-type ZAM — not a monitor ZAM. For conventional zone monitoring applications, a monitor ZAM is required. Verify the control panel has a ZAM address slot available and that the firmware version supports the intended control function before installation. A separate 24 VDC power input from a listed fire alarm power supply may be required for relay coil activation depending on installation.

For more information, contact the Life Safety Consultants team at (888) 557-0558, or email us at: sales@lifesafetycom.com

Additional information

Weight .25 lbs
Dimensions 5.5 × 5.5 × 2 in
Condition

New

Part Type

Zone Addressable Modules (ZAM)

Manufacturers

Simplex

 

 

 

 

 

Description

  • MAPNET II zone adapter modules (ZAMs) provide an addressable interface between conventional zone devices and the host fire alarm control panel.
  • Monitor ZAMs provide status monitoring and supervision of an initiating device circuit (IDC) zone and are used for circuits with non-addressable detectors and for other contact closures such as waterflow and tamper switches or non-addressable manual stations. Different models of Monitor ZAMs are available for two-wire IDCs Class B, or Class A, and for four-wire IDCs with Class B IDC input. Each type required a separate 24 VDC input power from a listed fire alarm power supply.
  • Signal ZAMs supervise and operate 24 VDC notification appliances, speakers, and telephone circuits. Output capacity is up to 2 A @ 24 VDC, or 50 W of 25 VRMS speakers, or up to three simultaneously activated firefighter phones. The signal ZAM is available for either Style Y/Class B or Style Z/Class A operation for notification appliance circuits.

 

Features

  • MAPNET II ZAMs provide an addressable interface to conventional fire alarm zone circuit devices** including:
    • Initiating devices (Monitor ZAM)
    • Notification appliance circuits (Signal ZAM)
    • Control relays (Control ZAM)
  • These ZAMs are compatible with the following Simplex® fire alarm control panels when equipped with MAPNET II communications:
    • 4100/4100U Series fire alarm control panels
    • 4100 Series Universal Transponders
    • 4120 Series Network node fire alarm control panels
    • 4020 Series fire alarm control panels
    • 2120 Communicating Device Transponders
  • MAPNET II communications can be wired:
    • NFPA Style 4/Class B or Style 6/Class A
    • Style 4/Class B communications may be wired either “T” tapped or In/Out
  • Convenient DIP switch address selection
  • UL listed to Standard 864