Gamewell-FCI Detector & Module Replacement Guide

Gamewell-FCI addressable detectors and modules are the sensing and control backbone of E3 Series®, Smart Loop Panel, and Identiflex systems. Whether you’re replacing a failed detector head, adding a monitor module, or expanding a signaling line circuit, sourcing the correct part is essential for maintaining system compliance and UL listing. This guide covers the most common Gamewell-FCI fire alarm replacement parts in our detector and module categories.

Gamewell-FCI Addressable Detectors

Velociti® Series — ASD & ATD Detectors

The Gamewell-FCI Velociti® detector platform uses CLIP or analog-addressable protocol. These detectors communicate continuously with the panel, reporting clean signal levels and enabling early detection.

  • ASD-PL3 — Analog photoelectronic sensor. The most widely deployed Gamewell-FCI detector for general occupancy spaces.
  • ASD-PL3R — Same as ASD-PL3 with remote test capability.
  • ASD-PTL3 — Dual photoelectric-thermal sensor combining smoke and heat detection.
  • ATD-L3 — Fixed 135°F thermal sensor for dusty, dirty, or high-humidity areas.
  • ATD-L3R — Rate-of-rise plus fixed 135°F thermal sensor.
  • ATD-L3H — High-temperature 190°F fixed thermal sensor for kitchens or near HVAC.
  • ASD-LS3 — High-sensitivity laser replacement sensor for clean rooms and very early warning detection applications.

XP95 / Apollo Protocol Detectors (Identiflex Systems)

For legacy Identiflex 610, 632, and 650 systems, Gamewell-FCI uses Apollo XP95 protocol devices. Common replacements include the 55000-650APO XP95 photoelectric detector and the SA5150-650APO Soteria detector. The OSI-RI-GW intelligent reflector-type linear optical beam detector is also available for large open-area protection.

Duct Detectors

HVAC duct-mounted smoke detection is required by NFPA 72 in most commercial applications. Gamewell-FCI duct detector models include the SS-PD photoelectric duct detector, SL-2000-P photoelectric duct smoke head, and SL-DA4R-P analog addressable duct detector with relay output.

Gamewell-FCI Addressable Modules

Monitor Modules (Initiating Device Circuit Interfaces)

  • AMM-2F — Single Class B monitor module; standard single-zone input for most E3 Series applications.
  • AMM-2IF — Dual-input addressable monitor module; two independent Class B monitor points in one address slot.
  • AMM-4F — Four-input Class A monitor module for Style D/E initiating circuits.
  • AMM-4SF — Addressable sub-loop Class A module for distributed configurations.
  • AMM-2RIF — Dual input/output module combining monitoring and relay output.
  • PIM-SS — 10-input monitor module for high-density monitoring applications.

Output & Control Modules

  • AOM-2RF — Addressable output relay control module. Dry contact output for door holders, elevator recall, HVAC shutdown, and auxiliary functions.
  • AOM-2SF — Addressable output signal module for supervised notification appliance circuits.
  • AOM-TELF — Addressable telephone monitor module for firefighter telephone systems.

Multi-Module Units

For high-density installations, Gamewell-FCI offers multi-module units including the MMI-6SF (6-zone sub-loop input), MMI-10F (10-input monitor), MMO-6RF (6-relay output), and MMO-6SF (6-signal output). Chassis accessories including MBB-2, MBB-6, and MCH-6 mounting chassis are required for multi-module installations.

Find Your Gamewell-FCI Detector or Module

Life Safety Consultants stocks both current-production and legacy Gamewell-FCI parts. Browse our complete Gamewell-FCI fire alarm replacement parts inventory or contact us if you need help matching a part number to your system. Same-day shipping on most orders.