Notifier (HS-NCM-WSF-2) High-speed network communications module, wire and fiber-optic cable interface (single-mode) .

$2,165.63

SKU: HS-NCM-WSF-2 Brand:

Out of stock

The Notifier HS-NCM-WSF-2 High-Speed Network Communications Module provides critical network interface connectivity for advanced fire alarm and emergency notification systems. Designed for seamless integration with Notifier addressable fire alarm panels, this single-mode fiber-optic and wire interface module enables robust, high-speed communication across complex networked fire detection environments.

Engineered for reliability in mission-critical commercial and institutional facilities, the HS-NCM-WSF-2 supports comprehensive network communications for large-scale fire alarm infrastructure. Its advanced design allows for flexible signal transmission between fire alarm control panels, allowing installers to create extensive, interconnected emergency notification systems in multi-building campuses, healthcare complexes, educational institutions, and high-rise commercial structures.

Key Features

  • Single-mode fiber-optic and wire interface support for maximum network flexibility
  • Compatible with Notifier addressable fire alarm control panels and network architectures
  • High-speed data transmission with low latency communication protocol
  • Ruggedized electronics designed for consistent performance in challenging environmental conditions
  • Supports comprehensive network diagnostics and fault isolation
  • Compliant with NFPA 72, UL 864, and UL 2572 emergency communication system standards

Technical Specifications

  • Communication Interface: Single-mode fiber-optic and wire
  • Network Protocol: Proprietary Notifier high-speed communication
  • Operating Temperature Range: 32°F to 120°F (0°C to 49°C)
  • Relative Humidity: 10% to 93% non-condensing
  • Dimensions: Compact form factor, panel-mountable
  • Power Requirements: 24VDC, low current draw

Professional fire alarm installers and system integrators will appreciate the HS-NCM-WSF-2’s robust design and seamless compatibility with existing Notifier fire alarm infrastructure. The module’s advanced network communication capabilities ensure reliable, real-time emergency signal transmission across complex facility layouts.