The Simplex 4098-9601 is a TrueAlarm photoelectric smoke detector for conventional 2-wire and 4-wire initiating device circuits (IDCs). Unlike analog addressable detectors that report chamber values to the panel, the 4098-9601 uses an on-board microprocessor with TrueAlarm drift compensation to make its own alarm decision locally — providing intelligent detection on conventional IDC wiring without requiring an addressable loop controller.
The 4098-9601 uses a louvered chamber design that directs airflow to the photoelectric sensing element, improving smoke capture in open-air ceiling installations. Sensitivity is rated at a nominal 2.8%/ft obscuration (standard sensitivity). A magnetic test feature initiates a functional alarm and identifies general sensitivity status via the detector LED — allowing testing without aerosol or removing the head from the base.
- TrueAlarm photoelectric sensing with drift compensation
- Conventional 2-wire or 4-wire IDC operation
- Nominal 2.8%/ft obscuration, standard sensitivity
- Magnetic functional test activation
- Multi-function LED for normal and alarm status
- Available bases for 2-wire, 4-wire, and auxiliary relay output configurations
- UL Listed to Standard 268; FM, CSFM, and MEA (NYC) Approved
The 4098-9601 has been discontinued by Simplex. The current replacement is the 4098-5601 photoelectric detector. Existing 4098-9601 units in service may remain per AHJ guidance, but base compatibility should be verified when substituting 4098-5601 heads on existing bases during replacements.
For more information, contact the Life Safety Consultants team at (888) 557-0558, or email us at: sales@lifesafetycom.com
For more information, contact the Life Safety Consultants team at (888) 557-0558, or email us at: sales@lifesafetycom.com
Additional information
| Weight | .25 lbs |
|---|---|
| Dimensions | 4 × 4 × 2 in |
| Condition | New |
| Part Type | Photoelectric, Smoke Detector |
| Manufacturers | Simplex |
| Compatible Panels | Conventional 2-wire and 4-wire IDC panels (panel-agnostic conventional operation) |
| Compatible Bases | 2-wire bases, 4-wire bases, auxiliary relay output bases |
| Cross Reference | 4098-9605 (3.5%/ft special application sensitivity), 4098-5601 (current replacement) |
| Type | Photoelectric smoke detector, Circuit: Conventional 2-wire or 4-wire IDC, Sensitivity: 2.8%/ft nominal (standard), Test: Magnetic functional test, Standards: UL 268, FM, CSFM, MEA (NYC), Status: Discontinued (replacement: 4098-5601) |