Simplex (2190-9163) Zone Addressable Module (ZAM) 0617610

$299.00

SKU: 2190-9163 Brand:

IDNet and MapNet II surface mount, control relay ZAM

The Simplex (2190-9163) Zone Addressable Module (ZAM) 0617610 is a zone addressable modules (zam) manufactured by Simplex. This product is designed for commercial fire alarm system applications and meets NFPA 72 installation requirements.

Key Features

  • Zone Addressable Modules (ZAM) for commercial fire alarm applications
  • Meets NFPA 72 requirements for fire alarm systems
  • Designed for replacement and maintenance applications

Compatible Panels

  • 2120, 4008, 4010, 4010ES, 4020, 4100, 4100ES, 4100U

For more information, contact the Life Safety Consultants team at (888) 557-0558, or email us at: sales@lifesafetycom.com

Additional information

Weight .25 lbs
Dimensions 5.5 × 5.5 × 2 in
Condition

New

Part Type

Zone Addressable Modules (ZAM)

Manufacturers

Simplex

Compatible Panels

2120, 4008, 4010, 4010ES, 4020, 4100, 4100ES, 4100U

Cross Reference

0617610

Type

Control relay ZAM, Relay output: DPDT, Protocol: IDNet and MAPNET II, Mount: Surface, Dimensions: 5.5 x 5.5 x 2 in, Weight: 0.25 lb, Condition: New

 

 

 

 

 

Description

  • MAPNET II zone adapter modules (ZAMs) provide an addressable interface between conventional zone devices and the host fire alarm control panel.
  • Monitor ZAMs provide status monitoring and supervision of an initiating device circuit (IDC) zone and are used for circuits with non-addressable detectors and for other contact closures such as waterflow and tamper switches or non-addressable manual stations. Different models of Monitor ZAMs are available for two-wire IDCs Class B, or Class A, and for four-wire IDCs with Class B IDC input. Each type required a separate 24 VDC input power from a listed fire alarm power supply.
  • Signal ZAMs supervise and operate 24 VDC notification appliances, speakers, and telephone circuits. Output capacity is up to 2 A @ 24 VDC, or 50 W of 25 VRMS speakers, or up to three simultaneously activated firefighter phones. The signal ZAM is available for either Style Y/Class B or Style Z/Class A operation for notification appliance circuits.

 

Features

  • MAPNET II ZAMs provide an addressable interface to conventional fire alarm zone circuit devices** including:
    • Initiating devices (Monitor ZAM)
    • Notification appliance circuits (Signal ZAM)
    • Control relays (Control ZAM)
  • These ZAMs are compatible with the following Simplex® fire alarm control panels when equipped with MAPNET II communications:
    • 4100/4100U Series fire alarm control panels
    • 4100 Series Universal Transponders
    • 4120 Series Network node fire alarm control panels
    • 4020 Series fire alarm control panels
    • 2120 Communicating Device Transponders
  • MAPNET II communications can be wired:
    • NFPA Style 4/Class B or Style 6/Class A
    • Style 4/Class B communications may be wired either “T” tapped or In/Out
  • Convenient DIP switch address selection
  • UL listed to Standard 864