Edwards (SIGA-MCC1) Single input module

$95.91

SKU: SIGA-MCC1 Brand:

Out of stock

The Edwards SIGA-MCC1 Single Input Module is a precision-engineered relay interface designed for comprehensive fire alarm system integration in complex commercial environments. This compact addressable module provides critical signal conversion and monitoring capabilities, enabling seamless communication between detection devices and control systems across various building infrastructure networks.

Engineered for professional fire alarm installation, the SIGA-MCC1 delivers reliable supervised input monitoring for conventional devices within addressable fire alarm panels. Its robust design allows integration with multiple system architectures, facilitating precise signal transmission and supervision for critical life safety applications in commercial, institutional, and industrial facilities.

Installers and system designers can leverage this module’s advanced functionality to expand monitoring capabilities, enabling comprehensive fire detection and response strategies across diverse building environments such as office complexes, healthcare facilities, educational institutions, and industrial campuses.

Key Features

  • Supervised single input channel for conventional detection devices and auxiliary monitoring points
  • Compatible with Edwards SIGNATURE Series fire alarm control panels and addressable communication loops
  • NFPA 72 compliant design with built-in short circuit isolation and fault monitoring
  • Low-profile form factor supporting dense panel configurations and space-constrained installations
  • Wide operating temperature range (-20°F to 150°F) for versatile deployment scenarios
  • UL Listed and meets rigorous agency standards for life safety equipment

Technical Specifications

  • Operating Voltage: 15-32 VDC
  • Standby Current: < 300 µA
  • Alarm Current: 6.0 mA typical
  • Operating Temperature: -20°F to 150°F (-29°C to 66°C)
  • Dimensions: 6.5″ x 4.5″ x 1.5″ (approximate)
  • Agency Listings: UL, FM, CSFM

Typical application scenarios include HVAC shut-down interfaces, door release mechanisms, elevator recall systems, and auxiliary notification device monitoring within comprehensive fire alarm network architectures.